15 TROUBLESHOOTING: Run Time is Short BATTERIES ARE LOW ON WATER • Add water, never acid, to cells (distilled water recommended). • DO NOT OVER WATER. • For fully charged standard deep-cycle batteries, add water to the level of 1/8 below bottom of vent well (see diagram A below). • For fully charged plus series batteries, add water to the maximum water level indicator (see diagram B below). • If the batteries are discharged, only add water if the plates are exposed. Add just enough water to cover the plates, then charge the batteries. Once fully charged, add water to the proper level indicated above. • After watering, secure vent caps on batteries. DIAGRAM A DIAGRAM B Add water to the level of 1/8" below bottom of vent well Add water to the maximum water level indicator CHARGER IS NOT PROPERLY SET FOR BATTERIES Dip switches are located behind the SPE white sticker. Peel back corner of sticker for access. See page 16 for proper setting of the dip switches.