92534-92_GeneSys_TroubleShooting_Manual
8 TROUBLESHOOTING: Poor Water Recovery WATER RECOVERY TANK IS FULL Empty the recovered water in an approved location. DIRTY OR WORN SQUEEGEE BLADES Disconnect the vacuum hose from the squeegee. Remove the squeegee from the machine by loosening the 2 black knobs. Inspect the edge of the squeegee blades for wear and debris. Remove retainers and squeegee blades for edge rotation and/or replacing. Clean sharp squeegee blade edges will enable the squeegee to recover water from the cleaned floor more efficiently. RECOVERY HOSE LOOSE OR KINKED The recovery hose is connected to the squeegee and to the recovery tank. Inspect both end connections for proper sealed attachment, cracks, holes or kinked hose sections. Also inspect the recovery hose for blockages or obstructions. SQUEEGEE OUT OF ADJUSTMENT Put the squeegee down and adjust by setting the squeegee wheels .060” up from the floor’s surface. This can be done with feeler gauges or by removing the .060” thick timer cover and use as a gauge. Use two 9/16” wrenches for the nuts. Set squeegee wheel height close to the .060” so the wheel almost touches. Slide .060” gauge or timer cover out and the wheel should not move. Tighten the nuts. Repeat for both wheels. Use your thumb to push down on the threaded shaft while setting height of wheel with top nut. Timer Cover